Kinetics experiments: choosing and analysing a method (Core Practical 9)
Edexcel IAL Chemistry · WCH16 Practical Skills in Chemistry II
Unit 6 kinetics questions ask you to choose a method, describe how it gives concentration over time, and process the results. Core Practicals 9a and 9b are taught in the Unit 4 lesson on iodine-propanone and clock reactions.
Continuous monitoring
Follow one reaction mixture over time.
- Colorimetry when one species is coloured (I2, MnO4-, Cu2+): choose a filter of the complementary colour, zero with water, and make a calibration curve of absorbance against concentration using standard solutions. Then read concentrations of the mixture from the curve.
- Gas volume or mass loss for reactions that give a gas.
- Sampling and quenching: withdraw portions at timed intervals, stop the reaction (CP9a adds the sample to sodium hydrogencarbonate to remove the acid catalyst) and titrate.
- pH or conductivity when the number or type of ions changes.
The result is a concentration-time graph, analysed with tangents and half-lives.
Initial rates and clock reactions
- Run several mixtures with different starting concentrations of one reactant, keeping the others and the total volume the same (add water).
- A clock reaction uses a small, fixed amount of a substance (such as thiosulfate) that removes a product until it runs out; then a colour appears. Only a small fraction of the reactants has been used, so the rate is close to the initial rate, and rate is proportional to 1/t. Too much thiosulfate would mean a large fraction reacts, so 1/t would no longer reflect the initial rate.
- Calculate each concentration in the mixture from the volumes: c(mixture) = c(stock) x V(stock) / V(total).
Errors and improvements
- Temperature must be constant: use a water bath and let solutions reach temperature before mixing.
- Start timing at the moment of mixing; judge the colour change consistently (a light sensor helps).
- Quenching must be quick and complete.
- 1/t gives an average rate over the time measured; a tangent at t = 0 on a concentration-time curve is a better initial rate.
Worked example
In a clock reaction, 7.50 cm3 of 0.100 mol dm-3 KI is mixed with other solutions to a total volume of 25.0 cm3. Find [I-] in the mixture.
- n(I-) = 0.00750 x 0.100 = 7.50 x 10-4 mol
- [I-] = 7.50 x 10-4 / 0.0250
Answer: 0.0300 mol dm-3
Check yourself
- 12.5 cm3 of 0.200 mol dm-3 sodium thiosulfate is made up to a total volume of 50.0 cm3 with acid and water. Calculate the concentration of thiosulfate in the mixture.
Show answer
0.0500 mol dm-3. 0.200 x 12.5 / 50.0 = 0.0500 mol dm-3.
- In a clock reaction, doubling [S2O82-] (all else constant) changes the time from 84 s to 42 s. What is the order with respect to S2O82-?
Show answer
1. Rate is proportional to 1/t, so the rate doubles: 2n = 84 / 42 = 2, n = 1.
- Why is only a small, fixed amount of thiosulfate used in an iodine clock reaction?
- So that the colour change is slower
- Because thiosulfate is a catalyst
- To keep the total volume constant
- So that only a small fraction of the reactants has reacted when the colour appears, giving the initial rate
Show answer
So that only a small fraction of the reactants has reacted when the colour appears, giving the initial rate. Many candidates missed this in October 2024.
- Why is a calibration curve made when using a colorimeter to follow a reaction?
- To convert absorbance readings into concentrations
- To find the wavelength of the filter
- To measure the temperature
- To remove the need for a blank
Show answer
To convert absorbance readings into concentrations. Standard solutions of known concentration give absorbance values to plot.
- In Core Practical 9a, how is each sample quenched?
- By adding starch
- By heating it
- By adding it to sodium hydrogencarbonate solution, which removes the acid catalyst
- By adding more iodine
Show answer
By adding it to sodium hydrogencarbonate solution, which removes the acid catalyst. Without H+ the reaction effectively stops.
- Why is 1/t only an approximation to the initial rate?
- It is an average rate over the time measured, not the rate at t = 0
- The time is measured in seconds
- It ignores the temperature
- It is always too large by a factor of 10
Show answer
It is an average rate over the time measured, not the rate at t = 0. Pearson's guide notes a tangent at t = 0 gives a more reliable initial rate.
- Which method would best follow the rate of a reaction in which purple MnO4- ions are used up, without disturbing the mixture?
- Sampling and titration
- Measuring gas volume
- Colorimetry
- Measuring mass loss
Show answer
Colorimetry. The colour fades, so absorbance can be read continuously.