Choosing instruments: range and resolution

Edexcel IAL Physics · WPH13 Practical Skills in Physics I

Choosing the right instrument is a planning skill examiners test on almost every paper. The key word is resolution.

Practise this in the app: instant marking and a fix for every mistake. Free, no email needed to start.

Practise this lesson

Resolution

The resolution of an instrument is the smallest measuring interval it can show. It is a source of uncertainty in a single reading. Typical school instruments:

InstrumentTypical resolutionGood for
Metre rule1 mmLengths from about 10 cm to 1 m
Vernier calipers0.1 mm (digital calipers 0.01 mm)External and internal diameters, a few mm to about 15 cm
Micrometer screw gauge0.01 mmWire diameters, sheet thickness, small spheres
Top-pan balance0.01 g or 0.1 gMasses
Digital stopwatch0.01 s (but human reaction time is about 0.2 s)Times of a few seconds or more
Protractor1°Angles
Thermometer1 °C (digital 0.1 °C)Temperatures
Digital multimeterThe last digit shownCurrent, p.d., resistance

Range

The instrument must be able to measure the whole range of values. A 30 cm ruler cannot measure a 1.5 m drop; a micrometer cannot measure a 5 cm diameter. On a multimeter, choose the smallest range that still covers the reading, because it shows more digits.

Justifying a choice

Justify an instrument by its resolution and the resulting percentage uncertainty: 'a micrometer has a resolution of 0.01 mm, so the percentage uncertainty in a 0.50 mm diameter is only 1%'. Examiners do not accept 'it is more accurate' or 'it is more precise' as a reason. Compare your percentage uncertainty with a benchmark and state explicitly that it is small enough.

When a stopwatch is acceptable

A stopwatch reads to 0.01 s, but the real uncertainty comes from reaction time. Time longer intervals (for example 20 oscillations) so the reaction-time uncertainty is a small fraction of the total, or use light gates and a data logger for short events.

Worked example

Should a student use a metre rule or a micrometer to measure the diameter of a 0.40 mm wire?

  1. Metre rule: resolution 1 mm, larger than the diameter itself, so it is useless.
  2. Micrometer: resolution 0.01 mm, uncertainty 0.005 mm.
  3. Percentage uncertainty = 0.005 / 0.40 x 100 = 1.3%

Answer: Use the micrometer: its percentage uncertainty is only about 1%

Key idea: Resolution is the smallest interval an instrument can show. Choose one whose range covers the measurement and whose resolution gives a small percentage uncertainty, and justify it with that resolution.

Check yourself

  1. Which instrument is most appropriate for measuring the diameter of a wire of about 0.3 mm?
    • Micrometer screw gauge
    • Metre rule
    • 30 cm ruler
    • Tape measure
    Show answer

    Micrometer screw gauge. Only the micrometer has a fine enough resolution (0.01 mm).

  2. Which instrument can measure the internal diameter of a pipe of about 2 cm?
    • Micrometer screw gauge
    • Top-pan balance
    • Vernier calipers, using the internal jaws
    • Protractor
    Show answer

    Vernier calipers, using the internal jaws. Vernier calipers have internal jaws for inside diameters; a micrometer only measures external sizes.

  3. A micrometer (resolution 0.01 mm) gives a diameter of 0.50 mm. Find the percentage uncertainty, using half the resolution.
    Show answer

    1.0 %. Uncertainty = 0.005 mm; 0.005 / 0.50 x 100 = 1.0%.

  4. Vernier calipers (resolution 0.1 mm) give a diameter of 18.6 mm. Find the percentage uncertainty, using half the resolution, to 2 s.f.
    Show answer

    0.27 %. Uncertainty = 0.05 mm; 0.05 / 18.6 x 100 = 0.27%.

  5. Which justification for choosing a micrometer would examiners credit?
    • It is more accurate
    • Its resolution is 0.01 mm, giving a small percentage uncertainty
    • It is more precise
    • It is the most expensive instrument
    Show answer

    Its resolution is 0.01 mm, giving a small percentage uncertainty. Justify with resolution and percentage uncertainty; 'accurate' and 'precise' are not accepted as substitutes for resolution.

  6. A p.d. of about 1.5 V is measured on a digital multimeter. Which range setting gives the best resolution?
    • 0 to 20 V
    • 0 to 200 V
    • 0 to 1000 V
    • 0 to 2 V
    Show answer

    0 to 2 V. The smallest range that still covers 1.5 V shows the most decimal places.

  7. Why is the uncertainty in a hand-timed reading usually much larger than the stopwatch's 0.01 s resolution?
    • Stopwatches are never calibrated
    • Human reaction time is about 0.2 s
    • Time cannot be measured precisely
    • The display rounds to the nearest second
    Show answer

    Human reaction time is about 0.2 s. Starting and stopping by hand adds a reaction-time uncertainty much bigger than the display's resolution.

Practise with instant feedback