Choosing the right instrument is a planning skill examiners test on almost every paper. The key word is resolution.
Resolution
The resolution of an instrument is the smallest measuring interval it can show. It is a source of uncertainty in a single reading. Typical school instruments:
| Instrument | Typical resolution | Good for |
|---|---|---|
| Metre rule | 1 mm | Lengths from about 10 cm to 1 m |
| Vernier calipers | 0.1 mm (digital calipers 0.01 mm) | External and internal diameters, a few mm to about 15 cm |
| Micrometer screw gauge | 0.01 mm | Wire diameters, sheet thickness, small spheres |
| Top-pan balance | 0.01 g or 0.1 g | Masses |
| Digital stopwatch | 0.01 s (but human reaction time is about 0.2 s) | Times of a few seconds or more |
| Protractor | 1° | Angles |
| Thermometer | 1 °C (digital 0.1 °C) | Temperatures |
| Digital multimeter | The last digit shown | Current, p.d., resistance |
Range
The instrument must be able to measure the whole range of values. A 30 cm ruler cannot measure a 1.5 m drop; a micrometer cannot measure a 5 cm diameter. On a multimeter, choose the smallest range that still covers the reading, because it shows more digits.
Justifying a choice
Justify an instrument by its resolution and the resulting percentage uncertainty: 'a micrometer has a resolution of 0.01 mm, so the percentage uncertainty in a 0.50 mm diameter is only 1%'. Examiners do not accept 'it is more accurate' or 'it is more precise' as a reason. Compare your percentage uncertainty with a benchmark and state explicitly that it is small enough.
When a stopwatch is acceptable
A stopwatch reads to 0.01 s, but the real uncertainty comes from reaction time. Time longer intervals (for example 20 oscillations) so the reaction-time uncertainty is a small fraction of the total, or use light gates and a data logger for short events.
Worked example
Should a student use a metre rule or a micrometer to measure the diameter of a 0.40 mm wire?
- Metre rule: resolution 1 mm, larger than the diameter itself, so it is useless.
- Micrometer: resolution 0.01 mm, uncertainty 0.005 mm.
- Percentage uncertainty = 0.005 / 0.40 x 100 = 1.3%
Answer: Use the micrometer: its percentage uncertainty is only about 1%
Check yourself
- Which instrument is most appropriate for measuring the diameter of a wire of about 0.3 mm?
- Micrometer screw gauge
- Metre rule
- 30 cm ruler
- Tape measure
Show answer
Micrometer screw gauge. Only the micrometer has a fine enough resolution (0.01 mm).
- Which instrument can measure the internal diameter of a pipe of about 2 cm?
- Micrometer screw gauge
- Top-pan balance
- Vernier calipers, using the internal jaws
- Protractor
Show answer
Vernier calipers, using the internal jaws. Vernier calipers have internal jaws for inside diameters; a micrometer only measures external sizes.
- A micrometer (resolution 0.01 mm) gives a diameter of 0.50 mm. Find the percentage uncertainty, using half the resolution.
Show answer
1.0 %. Uncertainty = 0.005 mm; 0.005 / 0.50 x 100 = 1.0%.
- Vernier calipers (resolution 0.1 mm) give a diameter of 18.6 mm. Find the percentage uncertainty, using half the resolution, to 2 s.f.
Show answer
0.27 %. Uncertainty = 0.05 mm; 0.05 / 18.6 x 100 = 0.27%.
- Which justification for choosing a micrometer would examiners credit?
- It is more accurate
- Its resolution is 0.01 mm, giving a small percentage uncertainty
- It is more precise
- It is the most expensive instrument
Show answer
Its resolution is 0.01 mm, giving a small percentage uncertainty. Justify with resolution and percentage uncertainty; 'accurate' and 'precise' are not accepted as substitutes for resolution.
- A p.d. of about 1.5 V is measured on a digital multimeter. Which range setting gives the best resolution?
- 0 to 20 V
- 0 to 200 V
- 0 to 1000 V
- 0 to 2 V
Show answer
0 to 2 V. The smallest range that still covers 1.5 V shows the most decimal places.
- Why is the uncertainty in a hand-timed reading usually much larger than the stopwatch's 0.01 s resolution?
- Stopwatches are never calibrated
- Human reaction time is about 0.2 s
- Time cannot be measured precisely
- The display rounds to the nearest second
Show answer
Human reaction time is about 0.2 s. Starting and stopping by hand adds a reaction-time uncertainty much bigger than the display's resolution.
Sources
- Pearson Edexcel International Advanced Subsidiary/Advanced Level in Physics specification (XPH11/YPH11), Issue 3
- Pearson qualifications: International Advanced Levels Physics (2018)
- Pearson examiners' report: IAL Physics WPH16/01, June 2024
- Pearson examiners' report: IAL Physics WPH13/01, October 2024
Last updated 8 November 2026. Spotted a mistake? Tell us.