Core practical 12: calibrating a thermistor as a thermostat
Core practical 12 calibrates a thermistor in a potential divider, so that the output p.d. can be used to read or control temperature, as in a thermostat.
Method
- Connect an NTC thermistor in series with a fixed resistor (or a variable resistor) across a d.c. supply, with a voltmeter across the fixed resistor (the output).
- Put the thermistor in a beaker of water with a thermometer close to it. Start with iced water and heat gradually, stirring all the time.
- At regular temperature intervals, record the temperature and the output p.d.
- Repeat while cooling, and average.
The calibration curve
Plot output p.d. against temperature. For an NTC thermistor, its resistance falls as temperature rises, so the fixed resistor takes a larger share of the supply p.d.: the output across the fixed resistor rises. Use the curve to read off the temperature for any measured p.d.
As a thermostat
A thermostat switches a heater off when the temperature reaches a set value. The output p.d. is fed to a switching circuit that operates at a fixed threshold p.d. Adjusting the variable resistor changes the temperature at which the threshold is reached. The calibration curve shows what output p.d. matches the chosen temperature.
Worked example
A 6.0 V supply is connected across a thermistor and a 2.2 kΩ resistor. At 20 °C the thermistor's resistance is 3.3 kΩ. Find the output p.d. across the fixed resistor.
- V_out = V_in x R / (R + R_th) = 6.0 x 2.2 / (2.2 + 3.3)
Answer: V_out = 2.4 V
Check yourself
- A 6.0 V supply is connected across a 2.2 kΩ fixed resistor and a thermistor of resistance 3.3 kΩ. Find the p.d. across the fixed resistor in V.
Show answer
2.4 V. V = 6.0 x 2.2 / 5.5 = 2.4 V.
- When the water is heated, the thermistor's resistance falls to 1.8 kΩ. Find the new p.d. across the 2.2 kΩ resistor (supply 6.0 V), in V.
Show answer
3.3 V. V = 6.0 x 2.2 / 4.0 = 3.3 V.
- With a 6.0 V supply, the output across a fixed resistor must be 4.0 V when the thermistor's resistance is 1.0 kΩ. Find the fixed resistance in kΩ.
Show answer
2 kΩ. The thermistor has 2.0 V across it, so the fixed resistor has twice its resistance: 2.0 kΩ.
- Why is the water stirred throughout the experiment?
- To cool the thermistor
- So the water, thermometer and thermistor are all at the same temperature
- To stop the water boiling
- To increase the current
Show answer
So the water, thermometer and thermistor are all at the same temperature. Without stirring, the thermometer and thermistor could be at different temperatures.
- As the temperature rises, what happens to the output p.d. across the fixed resistor in series with an NTC thermistor?
- It decreases
- It stays the same
- It falls to zero
- It increases
Show answer
It increases. The thermistor's resistance falls, so the fixed resistor takes a larger share.
- How is the calibration curve used?
- To find the supply p.d.
- To find the temperature from a measured output p.d.
- To find the resistance of the voltmeter
- To find the current in the heater
Show answer
To find the temperature from a measured output p.d.. That is what calibration means: linking the reading to the quantity being measured.
- In a thermostat circuit, why is a variable resistor used instead of a fixed one?
- To make the thermistor more sensitive to light
- To protect the supply
- To keep the output p.d. constant
- To set the temperature at which the circuit switches
Show answer
To set the temperature at which the circuit switches. Changing R changes the temperature at which the output reaches the switching threshold.